Back
//*******************************************************************************
// MSP430F26x Demo - SVS, POR @ 2.5V Vcc
//
// Description: The SVS POR feature is used to disable normal operation that
// toggles P1.0 by xor'ing P1.0 inside of a software loop.
// In the example, when VCC is above 2.5V, the MSP430 toggles P1.0. When VCC is
// below 2.5V, the SVS resets the MSP430, and no toggle is seen.
// ACLK= n/a, MCLK= SMCLK= default DCO ~ 1.045MHz
//
// MSP430F261x/241x
// -----------------
// /|\| XIN|-
// | | |
// --|RST XOUT|-
// | |
// | P1.0|-->LED
//
// B. Nisarga
// Texas Instruments Inc.
// September 2007
// Built with CCE Version: 3.2.0 and IAR Embedded Workbench Version: 3.42A
//******************************************************************************
#include <msp430x26x.h>
void main(void)
{
WDTCTL = WDTPW + WDTHOLD; // Stop watchdog timer
P1DIR |= 0x01; // Set P1.0 to output direction
SVSCTL = 0x60 + PORON; // SVS POR enabled @ 2.5V
for (;;)
{
volatile unsigned int i;
i = 50000; // Delay
do
(i--);while (i != 0);
P1OUT ^= 0x01; // Toggle P1.0 using exclusive-OR
}
}
|